Charging pump for the RAINMASTER Eco

In practice, the pump automatically starts intake due to decrease in pressure (pipe friction, intake level) only in a certain range. In this operating range, it evacuates the air from the pump independent of the suction line (for example, with initial start up operation). The pump boosts the intake performance of RM Eco, so that an intake level of additional 3 m can now be attained.

The charging pump unit is installed at the end of the intake line. The charging pump hangs on a float and moves up and down with the level of water in the tank. Thus water is always drawn from the cleanest area, just below the water surface.

 

 

 

Installation with system

1. Rainwater module RM Eco 8. Rainwater filter PURAIN
2. Mains water connection 9. Charging pump RM Eco-LP
3. Pressure line set with expansion vessel 10. Quiet inflow
4. Pressure line to house 11. Protective conduit pipe for suction line and sensor cable
5. Float switch 12. Rainwater line
6. Suction line 13. Wall bush MD100
7. Emergency overflow  

Technical Data

Dimension (H x W x D) / Weigt: 125 x 57 x 83 mm / 0,6 kg
Packaging dimensions (L x B x T) / weight: 310 x 220 x 160 mm / 1,5 kg
Power supply input: 24 V DC
Power intake: 20 W
max. pressure height: 3,2 m
max. volumene flow rate: 25 l/min
Pressure connection / hose connection: ½“ AG / Ø 14mm
Cable length x Cross section: 5 m x Ø 5 mm
Protection class: IP68

Intake performance characteristics of RM-Eco with charging pump

Intake performance characteristics of the RM Eco with and without RM Eco-LP charging pump.

The determined value must be above the represented intake line (RM Eco + RM Eco-LP) in the diagram.

Downloads

RM_ECO_LP_manual_.pdf

Installation and user manual RAINMASTER Eco LP

To top